- Description
- Inquiry
4TM REFRIGERATION COMPRESSOR OVERLOAD
Features:
1. Lower profile and light weight
2. Highly reliable performance
3. Meet require ments of IEC60079-15-2005 standard
Typical applications:
1. Compressor of refrigerator and ice-cabinet
2. Other electric protection appliance
Contact rating:
1. Form: 1 Form B
2. Switching current range: 2~25A
3. Switching voltage range: 110VAC、250VAC
4. Max.nominal current: 25A
Contact data:
1. Material: Ag+Cu, AgNi+Cu
2. Initial contact resistance: ≤50mΩ
3. Mechanical life: 3×10,000 ops
Electrical life: 1×10,000 ops
Characteristics data:
Type Overload UTC 70℃
current 25℃ (+0~20%A)
1/8HP 6.2A 1.1
1/7HP 6.8A 1.3
1/6HP 7.5A 1.5
1/5HP 8.5A 1.8
1/4HP 9.5A 2.0
1/3HP 11A 2.5
1/2HP 16A 3.5
Operate temperature(±5℃): 100-160℃
Resume temperature(±9℃): 61℃
Operate current time(25℃): 5-15S
Resume current time(25℃): ≥35S
Order designation:
1. Model: DRB
2. Current code: 10, 17,19, 20, 24, 26, 28, 33
3. Operate temperature code(℃):
J-100, K-105, L-110, M-115, N-120,
P-125, R-130, S-135, T-140, U-145,
V-150, W-155, X-160
4. Rusume temperature(℃): 61
5. Contact loading code:
A – 220VAC/0~15A
B – 220VAC/15~25A
6.The terminal type code: 1, 2, 3, 4, 5, 6, 7, 8
Example: DRB 26N61A1
Safety characteristics:
1. Insulation resistance:
The insulation resistance among terminal,
and cover should be ≥100MΩ under the
general condition.
2. Dielectric strength:
AC 1500V one minute between terminal
and cover under the general condition.
The environment condition of application:
1. Ambient temperature: -10 ~ +43℃
2. Relative humidity: ≤90% (25℃)
3. Mounting options:
6.3×0.8 / connector
M3.5×6 / fixed screw